Renesas Electronics /R7FA2A1AB /OPAMP /AMPCPC

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as AMPCPC

7 43 0 0 00 0 0 0 0 0 0 0 0 (0)PUMP0EN 0 (0)PUMP1EN 0 (0)PUMP2EN 0Reserved

PUMP1EN=0, PUMP0EN=0, PUMP2EN=0

Description

Operational Amplifier Switch Charge Pump Control Register

Fields

PUMP0EN

Charge Pump for AMP0 Enable

0 (0): Charge Pump for the AMP0 disabled

1 (1): Charge Pump for the AMP0 enable

PUMP1EN

Charge Pump for AMP1 Enable

0 (0): Charge Pump for the AMP1 disabled

1 (1): Charge Pump for the AMP1 enable

PUMP2EN

Charge Pump for AMP2 Enable

0 (0): Charge Pump for the AMP2 disabled

1 (1): Charge Pump for the AMP2 enable

Reserved

These bits are read as 00000. The write value should be 00000.